• Örnek Mah. Ercüment Batanay Sk. No:14/E D:14 Zemin Kat Dumankaya İkon Ataşehir / İSTANBUL
  • +90 216 291 19 51
  • [javascript protected email address]

Arama Sonuçları..

Toplam 32 kayıt bulundu.
Polartronic® V – The Allrounder

Polartronic® V – The Allrounder

  Teknik Özellikler: Measurement scales °Optical rotation, °Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L) up to 1000 scales freely definable Measuring range ± 360° / ± 259°Z Resolution 0.001° / 0.01°Z Precision ± 0.005° / ± 0.015 °Z * Reproducibility ± 0.001° / ± 0.01 °Z Sensitivity  Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 405, 435, 546, 578, 589, 633, 882 nm (others upon request) Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different models, 10 to 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless-steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ touchscreen, 800 x 480 pixel, 16 bit colors Operation Touchscreen, keyboard**, mouse**, barcode-reader**, remote via PC** Interface / Communication RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), LAN Conformity  International Pharmacopoeia, OIML, ASTM, ICUMSA, Australian Standard K157    

https://www.info-tek.com.tr/polaar-serisi-polarimetreler

Multi-Range Vacuum Gauge PIZA 111 cr - gold

Multi-Range Vacuum Gauge PIZA 111 cr - gold

With the Multi-Range Vacuum Gauge types PIZA 111 and PIZA 111 cr – gold, you can measure absolute pressures in the vacuum range which is created by water jet pumps, diaphragm pumps, piston pumps, rotary vane pumps and similar devices. The surfaces of the different wetted parts of the sensor for the PIZA cr - gold have been specially treated, making it highly resistant to chemicals. The Multi-Range Vacuum Gauges are supplied as a hand-held instrument. The range of applications for the Multi-Range Vacuum Gauge is determined by the following characteristics: - Measuring range 1050 mbar to 0.001 mbar, SP1 function display, with automatic switchover between capacitive and Pirani measuring ranges. - Capacitive absolute pressure measurement in the range from 5 (10) to 1050 mbar; SP 2 function display. - Vacuum measurement according to the pirani principle in the range from 0.001 to 10 (5) mbar; SP 3 function display. - Two-point calibration of the capacitive measuring range - Two-point calibration of the Pirani measuring range - High display resolution in digital read-out - High display speed Scope of delivery: vacuum sensor, KF16 flange, 8 – 10 mm stepped hose nozzle, cable, AC/DC adapter and 9V battery.

https://www.info-tek.com.tr/multi-range-vacuum-gauge-piza-111-cr-gold

Lauda TC1

Lauda TC1

For the first time, the compact TC1 offers maximum precision and ease of use, even for manual devices. Precisely repeatable and with a high resolution, measurements are made problem-free for the first time with the integrated assistant. No other device in this class measures more precisely. Also featured are integrated standard methods, an acoustic measuring assistant, GLP-compliant user management and extendibility using the compact PTT+, which not only makes temperature control thermostating highly precise but also saves space.

https://www.info-tek.com.tr/lauda-tc1

LAUDA Measuring stand S 5

LAUDA Measuring stand S 5

The measuring stand S 5 The S 5 is the actual measuring station of the PVS system. The head of the stand-alone measuring stand S 5 is comprised of the opto-electronic meniscus detectors as well as the entire micro-processor control of the measuring process including miniature pump and valves in the head of the unit. The measuring time of the sample is determined to the millisecond using a processor-controlled infrared light sensor. The robust micro-pump for pushing the sample up into the measuring ball as well as the chemicalresistant valves in the head of the stand make reliable continuous operation possible.

https://www.info-tek.com.tr/lauda-measuring-stand-s-5

LAUDA TD 1 C

dvanced measurement area up to 300 mN/m or 5 g Automatic maximum detection Output of the measured values to optional printer at the touch of a button Automatic measurement value corrections according to Zuidema and Waters Semi-automatic calibration in three accuracy levels with calibration weights Input of ring/plate dimensions possible Storage of up to 500 measurement results with parameters Numeric, user-defined sample designation

https://www.info-tek.com.tr/lauda-td-1-c

Lauda Scientific surface analyzer LSA 60

Lauda Scientific surface analyzer LSA 60

robust and precise measurement of contact engel versatile automatic dosing system available large sample stage with precise z-axis for easy handling extremely accurate surface tension measurements using the pendant drop method budget- friendly entry level device with high end accuracy

https://www.info-tek.com.tr/lauda-scientific-surface-analyzer-lsa-60

Ubbelohde Viscometer

Ubbelohde Viscometer

Ubbelohde Viscometers for automatic cleaning For automatic and stopwatch measurement. With screw connections and aspirating tube for permanent installation. Recommended for automatic cleaning with LAUDA VRM modules. • ISO 3105, DIN 51562, BS 188, NFT 60-100 • Filling volume: 18...22 ml • Total length: approx. 290 mm • Measurement accuracy: ±0.2 %

https://www.info-tek.com.tr/ubbelohde-viscometer-1

VariRef – Refractometer

VariRef – Refractometer

VariRef C VariRef B VariRef A Measuring scales Refractive Index (RI), Sucrose (% Brix)Standard scales included, freely definable scales Refractive Index (RI), Sucrose (% Brix), USG Measuring range 1.2900 – 1.5800 RI / 100% Brix 1.29000 – 1.58000 RI / 100% Brix1.32000 – 1.70000 RI / 100% Brix 1.320000 – 1.580000 RI / 100% Brix Precision ± 0.0001 RI* / ± 0.05% Brix* ± 0.00002 RI* / ± 0.02% Brix* ± 0.00002 RI / ± 0.02% Brix* Repeatability ± 0.0001 RI / ± 0.05% Brix ± 0.00002 RI / ± 0.02% Brix ± 0.000005 RI / ± 0.006% Brix Resolution 0.0001 RI / 0.05% Brix 0.00001 RI / 0.01% Brix 0.000001 RI / 0.001% Brix Ambient temperature + 10 °C to + 40 °C Temperature measurement NTC sensor Temperature range 5 °C to 80 °C 5 °C to 100 °C 20 °C (others upon request) Temperature precision / resolution ± 0.03 °C* / 0.01 °C Minimum sample volume 0,6 ml Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C) Measurement mode Single sample or flow through measurement (with optional compartment door) Prism Sapphire Sapphire / YAG Sapphire Light source / wavelength LED, interference filter 589 nm Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC / Tablet / Smartphone*** Interfaces Ethernet 10/100/1000, RS232, SH connector, USB, WLAN**, Modbus**, Canbus**, Profibus** Conformity International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others Power VAC 90-265; 50/60 Hz; 150 W max. Dimensions With display: 310 x 220 x 250 mm (w x d x h); without display: 310 x 220 x 150 mm (w x d x h) Highlights Modularity; user friendliness; fast temperature control; easy cleaning; variety of complete special sample room doors, e.g. for single or flow through measurements or for solid samples; the self-checking capabilities for cleanliness; environment temperature effects; calibration and more result in a virtually maintenance free product; 21 CFR Part 11 conform; ELN; LIMS ready

https://www.info-tek.com.tr/variref-refractometer

Coloromat® 100

Coloromat® 100

SPECIFICATIONS Coloromat 100 – V2 Optics Single beam photometer Wavelength range 340 – 900 nm* Pre-installed filters 560, 420, 720 nm FWHM 420 nm = 4 nm** 720 and 560 nm = 7 nm** Wavelength selection Via touch screen Light source LED Measuring range 0 – 16,000 ICUMSA Units (IU) Measuring accuracy ± 0.020 extinction at 420 nm ± 0.010 extinction at 560 nm ± 0.010 extinction at 720 nm ± 0.020 extinction at optional filters Resolution extinction 0.001 Resolution ICUMSA 1 IU Accuracy IU ± 10 % for colors < 20 IU ± 5 % for colors > 20 IU Operator Interface Touch screen for direct functions and alphanumerical inputs Data presentation Graphic display Data output RS232C & USB Operating temperature 10 – 40°C Languages English and German / Indonesian / Russian / Spanish   • Objective and repeatable measurements • 3 fixed wavelengths 340, 420 and 720 nm • Very narrow band width • 6 optional wavelengths (in the range of 340 - 900 nm)* • Automatic wavelength setting • Polarimeter cells up to 100 mm usable • Single or flow through measurements • Remote control via PC • Data output to PC or to directly connected printer, also via USB • Up to 250 methods programmable • GLP / GMP conform documentation • Largly maintenanee free   * For WL < 500 nm and > 700 nm, additional LED's may be required to ensure measurement accuracy and stability ** This very narrow half-value width enables high measurement accuracy as well as very good repeatability

https://www.info-tek.com.tr/coloromat-100

Purity Analyzer

Purity Analyzer

Purity Analyser The market leader for Purity Analyser The Schmidt + Haensch Purity Analyser is an inherent part in the analysis of the sucrose content. It is applied at payment laboratories of the cane and beet sugar receptions. The open modular structure of the Schmidt + Haensch instrumentation allows the direct, flexible coupling of different instruments. The Purity Analyser is the coupling of the Refactometer (ATR Serie) to the Saccharomat® (Quartz-Wedge Polarimeter) or the Polartronic (Circular Polarimeter/Saccharimeter). Both instruments are linked to one electronic controller showing the calculated value %purity of the sugar solution according to “Schmitz-Table” respectively the “Weighing Method” on the same display. Even directly coupled the flexibility allows an independent use of each single instrument as well as the determination of direct measurements indicated in °Z, °Pol, %Brix according to the ICUMSA methods. Schmidt + Haensch instruments achieve uncompromisingly precise and highly effective measurement values.

https://www.info-tek.com.tr/purity-analyzer-1

High-Res Process Refraktometre

High-Res Process Refraktometre

SCHMIDT + HAENSCH is proud to present the in-Line Process Refractometer High Resulution 2  model. This inline refractometer is perfect for all applications where a measuring needs to be as precise as laboratory testing. The iPR-HR2 is unrivaled in accuracy and can most certainly be claimed the world’s most precise process sensor. With a special water cooling system, the iPR-HR2 not only allows measuring in hot process environments and cleaning in place (CIP) – it also and ensures reliable measurements throughout its long product life span.  SPECIFICATIONS iPR HR 2 Measuring range 1 1.3200 - 1.3720 RI / 0 - 25 Brix Measuring range 2 1.4200 - 1.6000 RI / 50 - 100 Brix Resolution 0.000005 RI / 0.002 Brix Reproducibility ± 0.00004 RI / ± 0.02 Brix at 25°C ± 0.01 Brix up to 2% Process temperature -10°C up to + 100°C (with water cooling installed) Ambient temperature -10 - 45°C Pressure load capacity MPa (145 psi, 10 bar) - up to 30 bar available with APV conncection External power supply 20 V - 30 V DC ( at 24 V and 0.11 A) Interfaces 2 insulated 4 - 20 mA analog outputs 2 digital output switch (up to 1 A) 1 serial output (RS232, alternativly RS485 or USB) Power supply 24 V DC Prism Sapphire Light source / wavelength 589 nm LED Process contact material Sapphire, Stainless steel or Hastelloy Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/high-res-process-refraktometre-2

Compact InLine Proses Refraktometre

Compact InLine Proses Refraktometre

SPECIFICATIONS iPR C 2 Measuring scales Refractive Index (RI), Sucrose (Brix) (already included) Up to 4 scales freely definable Measuring range 1.3200 - 1.4209 RI / 0 - 50 Brix Resolution 0.0001 RI / 0.05 Brix Accuracy ± 0.0002 RI / ± 0.15 Brix at 25°C ATC range Brix +10 to +50°C Process temperature - 10° to + 65°C Process pressure max. 30 bar Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Interfaces 1 insulated 4 - 20 mA analog output 1 digital output switch (up to 1 A) 1 serial output (RS232, alternatively RS485 or USB) Power supply 24 V DC Prism Sapphire Data output 4 - 20 mA Process contact material Stainless steel or Hastelloy Dimension 150 mm x ø 65mm, approx. 1000g Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/compact-inline-proses-refraktometre

Full Range Inline Process Refraktometre

Full Range Inline Process Refraktometre

SPECIFICATIONS iPR FR2 Measuring range 1 1.3200 - 1.5300 RI / 0-100 Brix Measuring range 2 1.4200 - 1.6000 RI / 50 - 100 Brix Resolution 0.00001 RI / 0.01 Brix Accuracy ±0.00007 RI / ± 0,05 Brix at 25° C Process temperature - 10°C to 150°C (with water cooling) Ambient temperature - 10° to + 45°C Pressure load capacity MPa (145 psi, 10 bar) - up to 30 bar available with APV conncection Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Interfaces 2 insulated 4 - 20 mA analog outputs 2 digital output switch (up to 1 A) 1 serial output (RS232, alternativly RS485 or USB) Power supply 24 V DC Prism Sapphire Light source / wavelength 589 nm LED Process pressure (max.) MPa (145 psi, 10 bar) Process contact material Sapphire, Stainless steel or Hastelloy Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/full-range-inline-process-refraktometre-1

Multi-Range Vacuum Gauge PIZA 111

Multi-Range Vacuum Gauge PIZA 111

With the Multi-Range Vacuum Gauge types PIZA 111 and PIZA 111 cr – gold, you can measure absolute pressures in the vacuum range which is created by water jet pumps, diaphragm pumps, piston pumps, rotary vane pumps and similar devices. The Multi-Range Vacuum Gauges are supplied as a hand-held instrument. The range of applications for the Multi-Range Vacuum Gauge is determined by the following characteristics: - Measuring range 1050 mbar to 0.001 mbar, SP1 function display, with automatic switchover between capacitive and Pirani measuring ranges. - Capacitive absolute pressure measurement in the range from 5 (10) to 1050 mbar; SP 2 function display. - Vacuum measurement according to the pirani principle in the range from 0.001 to 10 (5) mbar; SP 3 function display. - Two-point calibration of the capacitive measuring range - Two-point calibration of the Pirani measuring range - High display resolution in digital read-out - High display speed Scope of delivery: vacuum sensor, KF16 flange, 8 – 10 mm stepped hose nozzle, cable, AC/DC adapter and 9V battery.

https://www.info-tek.com.tr/multi-range-vacuum-gauge-piza-111

LAUDA TD4

LAUDA TD4

The TD4 is a compact ring/plate tensiometer, which, as a standalone device, offers maximum ease of use in research and development, as well as for quality control. The graphic operating unit with touch-screen enables accurate tracking of measurements (even time-dependent measurements). The pre-programmed standard methods, the GLP-compliant user management system, the optional equipment with a small Peltier-based thermostat (PTT+) and the intuitive user guiding make the TD4 a compact and precise measuring instrument.

https://www.info-tek.com.tr/lauda-td4

DHR

DHR

SPECIFICATIONS DHR 95 Calibration Distilled Water Prism Material Optical Glass Sample Temperature 5 - 60 Degree Celsius Ambient Temperature 5 - 40 Degree Celsius Automatic Temperature Correction 5 - 70 Degree Celsius for 0 - 80 Brix Dimensions (LxWxD) 115 x 54 x 30 mm Weight 85 Grams (without Batteries fitted) Power 2xAAA Batteries Ratings & Compliance IP65 Dustproof/Water Resistant, CE, RoHS DHR 95 Key Features• 2 measurement scales:-Brix with Automatic Temperature Correction (ATC)-Refractive Index• 5-digit, full view LCD screen• Results displayed in 2 seconds• Holster Carrying Case Available as AccessoryTypical applications of the models• Agriculture• Veterinary• Industrial• Beverage• Food• Wine   Range of Models S+H model Scale Range Resolution Accuracy DHR 95 (Standard Model)Code number 16004 Sugar % (Brix)Refractive Index (RI) 0 ‐ 951.33 ‐ 1.54 0.10.0001 ± 0.2± 0.0003 DHR HoneyCode number 16009 Sugar % (Brix)Water in Honey % 0 ‐ 9510 ‐ 30 0.10.1 ± 0.2± 0.2 DHR WineCode number 16010 % Mass w/wAlcohol Probable (AP) 0 ‐ 350 ‐ 22 0.10.1 ± 0.2± 0.2 DHR OeCode number 16011 % Mass w/w° Oechsle 0 ‐ 3530 ‐ 130 0.11 ± 0.2± 1 DHR SalineCode number 16012 Sugar % (Brix)Saline (NaCl) 0 ‐ 540‐ 28 0.10.1 ± 0.2± 0.2 DHR AquaCode number 16013 Seawater PPT (Part Per Thousand)Seawater Specific Gravity (SG) 0 ‐ 1801.000 ‐ 1.070 10.0005 ± 1± 0.001 DHR VetCode number 16014 Urine Specific Gravity (SG) small mammalUrine Specific Gravity (SG) large mammal 1.000 ‐ 1.0501.000 ‐ 1.050 0.00050.0001 ± 0.001± 0.001 DHR PGCode number 16015 Propylene Glycol % by volumePropylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR EGCode number 16016 Ethylene Glycol % by volumeEthylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR DEFCode number 16017 % BrixFor measuring AdBlue© 0 ‐ 540 ‐ 40 0.10.1 ± 0.2± 0.2 - Further scales upon request!

https://www.info-tek.com.tr/dhr

Saccharoflex 2020

Saccharoflex 2020

Specifications Saccharoflex 2020 Measuring scales Color grading of white crystal sugar acc. ICUMSA Measuring range 0 to 19.99 color units (CU) or derivative range Resolution 0.01 (CU) Precision ± 0.15 (CU) Reproducibility ± 0.15 (CU) Wavelengths 495 and 620 nm, tolerance 1%, mean waveband 20 nm Measuring time ≤ 1 sec Calibration Standards "0" to "6" of the Brunswick color type or ceramic standard Light source Tungsten halogen lamp 12 V, 20 W, base G4 Display LCD, one line, 16 characters, back illuminated Conformity ICUMSA method GS 2-13 (1998) Interfaces RS 232 C Dimensions 220 x 260 x 480 mm (w x d x h) Weight approx. 8,3 kg Highlights Precise and fast color type indication of white sugar crystals; reflectance factors at 495 and 620 nm are measured; measurement is done by use of the proven Taylor's law and an integrated sphere; great sample surface guarantees reliable measuring results; the instrument allows to measure also brown sugars due to the up to 19.99 CU extended measuring range; easy calibration by Brunswick color standards or longtime stable ceramic standards; the adjustable working voltage provides a high service life of the lighting unit

https://www.info-tek.com.tr/saccharoflex-2020

VariPol – Polarimeter

VariPol – Polarimeter

Teknik Özellikler:   Specifications VariPol C VariPol B Measurement scales ° Optical rotation, ° Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L),further scales freely definable Measuring range ± 89.9° Precision ± 0.01° * ± 0.005° * Repeatability ± 0.01° ± 0.005° Resolution 0.005° 0.001° Sensitivity Up to OD 3 Wavelength 1 or 2 wavelengths fixed, standard 589 nm, also available 365, 405, 436, 546 Measuring time 6 to 8 sec. over the entire measuring range Measuring tubes Up to 100 mm length; standard tubes, tubes with funnel or flow through; wetted parts: glass, stainless steel, Hastelloy Temperature measurement Pt1000 sensor (device) / NTC sensor (Quartz control plates and tubes) Sample temperature range 10 °C to 40 °C Temperature precision / resolution ± 0.1 °C* / 0.01 °C Peltier temp. regulation of the sample room 18 °C to 25 °C 10 °C to 40 °C Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C, with tube) Light source LED, interference filter Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC/Tablet/Smartphone*** Interfaces / Communication Ethernet 10/100/1000, RS232, USB, WLAN** Power VAC 90-265; 50/60 Hz; 150 W max Conformity International Pharmacopoeia, OIML, 21 CFR part 11, ICUMSA, Australian Standard K157 Dimensions With display: 430 x 300 x 270 mm (w x d x h); without display: 430 x 300 x 160 mm (w x d x h) Highlights Basic Polarimeter especially designed for pharmaceutical applications; Modularity; Fast measuring; Peltier system forautomatic temperature control; easy to calibrate; constant precision over the whole measuringrange, 21 CFR part 11ready; energy saving durable LEDs; ELN; LIMS ready  

https://www.info-tek.com.tr/aa-65-serisi-polarimetreler

bubble pressure tensiometer MPT C

bubble pressure tensiometer MPT C

Output of the measured values is optional via a printer or a data transmission software on the PC via the RS 232-interface. The measurement and the documentation of the temperature in the sample can also be carried out by means of an optional digital temperature probe. In addition to the proven PVDF-coated glass capillaries, steel capillaries (such as for highly alkaline samples) are available.

https://www.info-tek.com.tr/bubble-pressure-tensiometer-mpt-c

Lauda Scientific surface analyzer LSA  200

Lauda Scientific surface analyzer LSA 200

flexible automation with automatic x\y\z\ axes for the sample stage different lenses and cameras for every possible application optional revolutionary features such as the double wiev module for simultaneous top and side view and measurements on a single drop extremely versatile software package surface mater included

https://www.info-tek.com.tr/lauda-scientific-surface-analyzer-lsa-200

ATR L Dispersion Refractometer

ATR L Dispersion Refractometer

SPESIFICATIONS ATR-L Measuring scales Refractive index (RI) Measuring range 1.33200 - 1.70000 RI* / 100% Brix Resolution 0.00001 RI* / 0.01 Brix Precision ± 0.00004 RI* / ± 0.03 Brix Reproductibility ± 0.00004 RI* / ± 0.03 Brix Measuring time per sample 20 sec for all 7 wavelength after temperature stabilisation; single sample measurement Ambient temperature + 15° to + 40°C Automatic temperature compensationOperational temperatureTemperature stabilityTemperature precision Solid state Peltier-thermostatisation+ 10°C to + 80°C0.01°C± 0.03°C Detector CCD-linear array with 2048 elements Sample compartment Used materials: stainless steel, Black Delrin®, Teflon®, Viton®, FFKM sealing Prism YAG Light source / Wavelength 7 discrete LED's with fixed wavelengths 400, 450, 490, 545, 590, 660, 700 nm (others on request),wavelength accuracy ± 2 nm Display LCD, 16 x 16 characters, back illuminated Operation 20 key membrane including function keys Interfaces /Communication 1 x RS232 C, 1x parallel, USB optional Standards                                                           European and international Pharmacopoeia, various ASTM, ISO and DIN standards Dimensions / Weight Mesuring head, stainless steel: 260 x 190 x 220 mm (w x h x d); control unit: 220 x 110 x 290 mm (w x h x d); complete unit 8 kg Highlights                                                                                                     Automatic dispersion measurement at 7 wavelengths over the full range of visibile light (intermediate values interpolated)**;Powerful, internal Peltier temperature control guarantees the fastest measurements with highest accuracy

https://www.info-tek.com.tr/atr-l-dispersion-refractometer

Duo Visc

Duo Visc

Routine viscosity measurements demand a high level of precision both in temperature and time measurement. The Duo.Visc with its two independent thermoelectric Peltier heating/cooling systems allows to have the most stable and precise measurements without consuming valuable bench-space in the laboratory. The wide range of available capillaries covers the complete viscosity range. The easy to use Duo.Visc software helps to meet the requirements of today’s laboratories.

https://www.info-tek.com.tr/duo-visc

Multi-Range Vacuum Gauge MRV 3000 without Transducer

Multi-Range Vacuum Gauge MRV 3000 without Transducer

Measuring instrument for use in the coarse, fine and high vacuum ranges Can only be used with transducer and sensor line Digital measuring instrument RS 232 / RS 485 interface and analog voltage output Well-arranged membrane keypad Three relays for programming setpoint values - Can be used for controlling valves Alarm buzzer to indicate deviations from setpoint values The LCD panel is a dialog system for displaying the second unit of measurement Display digital LED in mbar/Torr, height 10 mm Resolution 1 digit Read-out 5 per sec Thresholds 3 x 250 VAC, 4 A, independent adjustable Switching accuracy/hysteresis +-1 digit Max. pressure depending on type 2 - 6 bar Power max. 25 W Vacuum connection depend on transducer Ambient conditions 0 - 35 °C and max. 90 % rh, 0 - 50 °C during storage

https://www.info-tek.com.tr/multi-range-vacuum-gauge-mrv-3000-without-transducer

TVT 2 Drop volume tensiometer

TVT 2 Drop volume tensiometer

Positioning accuracy in the micro-meter range Variable control of the feed rate by a factor of 300 using a Phase-Locked Loop (PLL) speed controller Automatic adaptation of the light sensor's intensity to the used liquids Quasi-static mode for very high surface ages Simple connection to LAUDA thermostats for thermostating and software-controlled recording of the temperature dependency Less than 1 ml sample necessary to record a measuring curve

https://www.info-tek.com.tr/tvt-2-drop-volume-tensiometer

LSA.BOB-M LAUDA MOBİLE SURFACE ANALYZER

LSA.BOB-M LAUDA MOBİLE SURFACE ANALYZER

mobile measuring instrument with innovative top view technology. suitable for measurements on surfaces with complex topography and onsite inspections highest precision for any contact angle range due to young-laplace fit of the drop. suitable for all drop sizes and liquids no limits for sample size surface mapping of the wetting properties with high spatial resolution down to 5mm, optional robot system and automatic sample stages optional automatic dosing system for measurements both on horizontal and vertical surfaces

https://www.info-tek.com.tr/lsa-bob-m-lauda-mobile-surface-analyzer

Saccharomat® V

Saccharomat® V

Measurement scales  °Z International Sugar Scale Measuring ranges – 35°Z to + 105°Z Resolution 0.01 °Z Precision ± 0.01 °Z Reproducibility ± 0.01 °Z Sensitivity Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 587, 882 nm Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different Models,  50, 100 or 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interface / Communication  RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN** Conformity  International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K157  

https://www.info-tek.com.tr/saccharomat-v

ATR P

ATR P

SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)

https://www.info-tek.com.tr/atr-p

LAUDA Contact Angle Surface Analyzer LSA100

LAUDA Contact Angle Surface Analyzer LSA100

Wetting of surfaces and solid-liquid-interaction can be precisely measured with contact angle instruments. The LAUDA Surface Analysers series LSA 60, 100 and 200 can be adapted to any laboratory requirement. Especially the easy handling and the very comprehensive software support the daily routine in the laboratory and allow precise measurement results. LAUDA Scientific offers you innovative features such as simultaneous measurements in projection and top-view, telecentric lenses for research applications or non-contact dosing systems.

https://www.info-tek.com.tr/lauda-contact-angle-surface-analyzer-lsa100

ATR BR

ATR BR

SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning

https://www.info-tek.com.tr/atr-br

Ring/Plate Tensiometer TD 3

Ring/Plate Tensiometer TD 3

Technical features   TD 3 Measuring range surface and interfacial tension mN/m 0…300 (ring method); 0…999 (plate method); resolution: 0.01 Density measurement kg/m3 0…2000; resolution: 1 Weight measurement mg 0…5000; resolution: 0.1 Measuring mode selection/parameter input   Ring/plate/density/weight/menu-driven Measuring point interval Minute 0...120, selectable Measurement memory Results max. 500, with date and time Ring correction   Automatic based on Zuidema and Waters Stability criterion   Standard deviation over option of 3…9 measurements Temperature range (PTT) °C 5…80 (±0.1) Magnetic stirrer   Integrated into the PTT, adjustable (10 levels) Stage movement mm/s 0.1…1 (10 levels) Interface   RS 232, Command remote control Control and evaluation   Command remote control (control, display, documented data storage) Ambient temperature range °C 10…40 Power consumption W 10 Dimensions (WxDxH) mm 245x205x335 Weight kg 9.5 Cat. No. 90…240 V; 50/60 Hz   LMT 850 incl. power supply unit

https://www.info-tek.com.tr/ringplate-tensiometer-td-3

White Light Smoke <b class=red>Measurement</b> System DIN 50055

White Light Smoke Measurement System DIN 50055

FTT ‘Duman Yoğunluğu Fotometrik Sistemi’ (DIN 50055), yanan malzemelerden gelen dumanı ölçen ekipmanlarla birlikte kullanılmak üzere tasarlanmıştır. Cihaz şunlardan oluşur: Işık kaynağı Işık ölçüm sistemi Kontrol ünitesi Işık Kaynağı, gazla dolu bir tungsten filaman lambasıdır. Lambanın gücü, Kontrol Ünitesinde bulunan düzenlenmiş bir güç kaynağı tarafından sağlanır. Işık Ölçüm Cihazı şunlardan oluşur: Lenslerin akromatik sistemi Silikon fotoelektrik hücre Yüksek kazanç düşük gürültü amplifikatörü Bu bileşenler, bir toplama merceğine sahip bir düzeneğe yerleştirilmiştir.

https://www.info-tek.com.tr/white-light-smoke-measurement-system-din-50055

PULVERISETTE 5 PREMIUM LINE BİLYALI DEĞİRMEN

PULVERISETTE 5 PREMIUM LINE BİLYALI DEĞİRMEN

TECHNICAL DATA Working principle impact force Optimal for material type hard, medium-hard, soft, brittle, tough, moist Number of grinding stations 2 Grinding tools grinding bowls and grinding balls Materials of the grinding tools agate, zirconium oxide, hardened stainless steel, hardmetal tungsten carbide Grinding bowl sizes 125, 150, 250, 420, 500 ml Grinding ball diameter 0.1 - 20 mm Max. feed size (depends on material) 10 mm Min. sample quantity 15 ml Max. sample quantity 450 ml Final fineness (depends on material) < 0.1 µm Typical grinding time down to analytical fineness 3 min Grinding process wet and dry Grinding in inert gas yes Gas pressure and temperature measurement yes Rotational speed of main disk 100-800 rpm Transmission ratio planetary disk / grinding bowl i relative = 1 : -2 Effective diameter of main disk 180 mm Centrifugal acceleration (g = 9.81 m/s²) 64 g Interfaces yes Electrical Details, additional voltages available upon request 200-240 V/1~, 50-60 Hz, 2800 watt Emission sound pressure level at the workplace according to DIN EN ISO 3746 (depending on the material to be ground, grinding bowls/balls, selected rotational speed) approx. LpAd = 84 dB Weight 110 kg Dimensions (W x D x H) bench top instrument 82 x 52 x 48 cm

https://www.info-tek.com.tr/pulverisette-5-premium-line

-->
3WTURK CMS v6.0
-->