Arama Sonuçları..
Toplam 92 kayıt bulundu.
Water Bath for evaporation Order No 1023
Applications For gentle steaming work with Erlenmeyer flasks and beakers.
https://www.info-tek.com.tr/water-bath-for-evaporation-order-no-1023Shaking Water Bath Order No 1083
Applications GFL Shaking Water Baths are particularly used whenever exactly reproducible temperatures are required for shaking tasks. Their scope of applications comprises incubations, fermentations, homogenisations, chemical and biochemical reactions, enzyme and tissue studies.
https://www.info-tek.com.tr/shaking-water-bath-order-no-1083Hybridisation Incubator Order No 7601
Due to the small quantity of necessary hybridisation liquid it is possible to work with a high concentration of probes or antibodies. Therefore, the Hybridisation Incubator 7601 is considered as the ideal unit for exact hybridisations of DNA and RNA probes with nucleic acid on filter paper and for incubations of protein blots with antibodies.
https://www.info-tek.com.tr/hybridisation-incubator-order-no-7601Mini Incubator Order No 4010
Mini Incubator 4010 is most suitable for incubations that demand exactly reproducible temperatures as well as for tempering, warming and drying of samples. The lift-up, see-through acrylic cover permits a clear view of the cultures in the interior cabinet.
https://www.info-tek.com.tr/mini-incubator-order-no-4010Mini Tube Roller Incubator Order No 4020
Universally applicable for incubations and hybridisations: Mini Tube Roller Incubator 4020. Due to its constant rotation speed of 13 rpm, it provides even results and high resolutions of the detections even when in continuous use. The lift-up, see-through acrylic cover permits a clear view of the cultures in the interior cabinet.
https://www.info-tek.com.tr/mini-tube-roller-incubator-order-no-4020Rocking Shaker Order No 3013
Applications This model has proven itself through reliable and perfect work, also for continuous operation, and is always called upon when the best possible supply of parallel cultures and cell lines is required, or for staining or discoloration of gels. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/rocking-shaker-order-no-3013MMM Ecocell 22 - ECO line
Convincingly cost saving laboratory dryer 22-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-22-eco-lineMMM INCUCELL 22 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 22-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume22 l depth350 mm width240 mm height300 mm Tray standard equipment2 pcs storage area (w × d)185×265 mm racks4 max. number distance between guide rails60 mm Maximal weight of the load*) inside the oven25 kg/oven per tray10 kg/tray Door 1 pcs External dimensions (including door and handle) depth560 mm diameter of the air branch outer / inner52/49 mm width406 mm height, incl. Feet (N) and Rolls (K)610 (N) Package dimensions (three layers carton) depth720 mm width500 mm depth810 mm Weight brut36 kg nett31 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)0,4 °C space deviation cca (±)1,1 °C Time required to reach 37 °C with closed air flap and voltage 230 V 70 min Heat emission at 37 °C 20 W Air exchange speed at 37 °C 4 per hour Electricity - mains 50/60 Hz max. power0,24 kW nominal voltage230 V current1,1 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-22-eco-lineIncubation/Inactivation Bath Order No 1102
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1102Shaking Water Bath Order No 1086
Applications GFL Shaking Water Baths are particularly used whenever exactly reproducible temperatures are required for shaking tasks. Their scope of applications comprises incubations, fermentations, homogenisations, chemical and biochemical reactions, enzyme and tissue studies.
https://www.info-tek.com.tr/shaking-water-bath-order-no-1086Orbital Shaker Order No 3015
Applications What counts when growing micro-organisms, cell and tissue cultures is a "reliable colleague" - an indispensable ingredient for successful work in biochemistry, microbiology, biotechnology, bacteriology and virology. Thus, this unit is particularly well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C
https://www.info-tek.com.tr/orbital-shaker-order-no-3015Rocking Shaker Order No 3014
Applications This model has proven itself through reliable and perfect work, also for continuous operation, and is always called upon when the best possible supply of parallel cultures and cell lines is required, or for staining or discoloration of gels. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/rocking-shaker-order-no-3014MMM Ecocell 55 - ECO line
Convincingly cost saving laboratory dryer 55-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-55-eco-lineMMM INCUCELL 55 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 55-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume55 l depth370 mm width400 mm height350 mm Tray standard equipment2 pcs storage area (w × d)380×335 mm racks4 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer / inner52/49 mm width620 mm height, incl. Feet (N) and Rolls (K)680 (N) Package dimensions (three layers carton) depth730 mm width700 mm depth875 mm Weight brut66 kg nett55 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 0,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 49 min Heat emission at 37 °C 30 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,3 kW nominal voltage230 V current1,3 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/incucell-55-eco-lineSaccharoflex 2020
Specifications Saccharoflex 2020 Measuring scales Color grading of white crystal sugar acc. ICUMSA Measuring range 0 to 19.99 color units (CU) or derivative range Resolution 0.01 (CU) Precision ± 0.15 (CU) Reproducibility ± 0.15 (CU) Wavelengths 495 and 620 nm, tolerance 1%, mean waveband 20 nm Measuring time ≤ 1 sec Calibration Standards "0" to "6" of the Brunswick color type or ceramic standard Light source Tungsten halogen lamp 12 V, 20 W, base G4 Display LCD, one line, 16 characters, back illuminated Conformity ICUMSA method GS 2-13 (1998) Interfaces RS 232 C Dimensions 220 x 260 x 480 mm (w x d x h) Weight approx. 8,3 kg Highlights Precise and fast color type indication of white sugar crystals; reflectance factors at 495 and 620 nm are measured; measurement is done by use of the proven Taylor's law and an integrated sphere; great sample surface guarantees reliable measuring results; the instrument allows to measure also brown sugars due to the up to 19.99 CU extended measuring range; easy calibration by Brunswick color standards or longtime stable ceramic standards; the adjustable working voltage provides a high service life of the lighting unit
https://www.info-tek.com.tr/saccharoflex-2020Incubation/Inactivation Bath Order No 1103
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1103Shaking Water Bath Order No 1092
Applications GFL Shaking Water Baths are particularly used whenever exactly reproducible temperatures are required for shaking tasks. Their scope of applications comprises incubations, fermentations, homogenisations, chemical and biochemical reactions, enzyme and tissue studies
https://www.info-tek.com.tr/shaking-water-bath-order-no-1092Orbital Shaker Order No 3017
Applications What counts when growing micro-organisms, cell and tissue cultures is a "reliable colleague" - an indispensable ingredient for successful work in biochemistry, microbiology, biotechnology, bacteriology and virology. Thus, this unit is particularly well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C
https://www.info-tek.com.tr/orbital-shaker-order-no-3017MMM Ecocell 111 - ECO line
Convincingly cost saving laboratory dryer 111-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-111-eco-lineMMM INCUCELL 111 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 111-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume111 l depth370 mm width540 mm height530 mm Tray standard equipment2 pcs storage area (w × d)520×335 mm racks7 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer / inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)860 (N) Package dimensions (three layers carton) depth730 mm width830 mm depth1060 mm Weight brut87 kg nett75 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 0,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 57 min Heat emission at 37 °C 45 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,3 kW nominal voltage230 V current1,3 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-111-eco-lineStarFish™ Work Station
Tüm manyetik karıştırıcılar için uyumluluk gösterir. Genel kullanım amaçlı tüm camlar ile kullanılır. Sentez, Distilasyon ve Ekstraksiyon çalışmaları kolaylıkla yapılabilinir. Tezgahınızda fazla yer kaplamaz. Kolay ve güvenli oluşu sayesinde kazalara sebebiyet vermeden çalışmaya olanak sağlar.
https://www.info-tek.com.tr/starfish-work-stationCase study: Rotary Evaporators at the University of Bristol
The outcome was that all 3 machines that had new seals replaced on the first day achieved an ultimate vacuum of 9 mbar.
https://www.info-tek.com.tr/university-of-bristol-rotary-evaporatorsIncubation/Inactivation Bath Order No 1104
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1104Thermolab Order No 1070
Applications THERMOLAB ® is versatilely applicable and exemplary when an excellent temperature constancy is called for, e. g. for polymerase chain reactions (PCR), for the preparation of enzyme and DNA tests or hybridisations
https://www.info-tek.com.tr/thermolab-order-no-1070MMM Ecocell 222 - ECO line
Convincingly cost saving laboratory dryer 222-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-222-eco-lineMMM INCUCELL 222 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 222-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume222 l depth520 mm width540 mm height760 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks10 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven70 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1095 (N) Package dimensions (three layers carton) depth860 mm width860 mm depth1260 mm Weight brut116 kg nett100 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1 °C Time required to reach 37 °C with closed air flap and voltage 230 V 79 min Heat emission at 37 °C 45 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,5 kW nominal voltage230 V current2 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-222-eco-lineVacuum Control-Box VCB 521 cv
Benchtop unit as digital, chemistry-resistant vacuum stabilizers. With integrated sensor, ventilation-, control- and check valve. Ceramic sensor integrated Accuracy in sum linearity, hysteresis, reproductibility < +-0.3% FS Sensor signal 0.5 to 4.5 V (optionally also 4..20 mA by jumper possible) Pressure indicator digital or graphically Switching- / control accuracy ±1 digit Output signal digital 24 VDC Communication interface RS 232, SUB-D plug 9-pole Operating voltage 90-264 VAC, 50/60 Hz, 30 W Output voltage 24 VDC Protective system IP 20 Working temperature 15 to 40°C Fuse (internal controller) 5 A Connection vacuum apparatus Hose nozzle DN 8 Connection vacuum pump Hose nozzle DN 8 Connection inert gas Hose nozzle DN 4 Connection water valve Binder plug 4-pole 24V DC Filling level sensor option.
https://www.info-tek.com.tr/vacuum-control-box-vcb-521-cvTVT 2 Drop volume tensiometer
Positioning accuracy in the micro-meter range Variable control of the feed rate by a factor of 300 using a Phase-Locked Loop (PLL) speed controller Automatic adaptation of the light sensor's intensity to the used liquids Quasi-static mode for very high surface ages Simple connection to LAUDA thermostats for thermostating and software-controlled recording of the temperature dependency Less than 1 ml sample necessary to record a measuring curve
https://www.info-tek.com.tr/tvt-2-drop-volume-tensiometerATR P
SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)
https://www.info-tek.com.tr/atr-pIncubation/Inactivation Bath Order No 1105
Applications The Water Bath is successfully used for heating up medical compresses/hot packs as well as for incubations and inactivations of cultures, e. g. for warming bacteriological media, processing chemical reactions or thawing frozen samples
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1105XRF Pellets – high throughput, high quality
32mm and 40mm pellet sizes Ejects pellet without awkward user handling Works seamlessly with Autotouch automatic press cycle Premium build material for durability Simple design for easy use
https://www.info-tek.com.tr/xrf-pellets-high-throughput-high-qualityMMM Ecocell 404 - ECO line
Convincingly cost saving laboratory dryer 404-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-404-eco-lineMMM INCUCELL 404 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 404-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume404 l depth520 mm width540 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven100 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width830 mm depth2085 mm Weight brut175 kg nett150 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1 °C Time required to reach 37 °C with closed air flap and voltage 230 V 41 min Heat emission at 37 °C 65 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,9 kW nominal voltage230 V current3,9 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-404-eco-lineIncubation/Inactivation Bath Order No 1108
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1108Pellet Press Dies | FTIR + XRF Dies
Ideal for producing high-quality pellets Evacuable for sample pellet clarity and quality Hardened Stainless Steel for durability Highly Polished Pellets Wide range of sizes and load capabilities Buy FTIR or XRF die
https://www.info-tek.com.tr/pellet-press-dies-ftir-xrf-diesMMM Ecocell 707 - ECO line
Convincingly cost saving laboratory dryer 707-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-707-eco-lineMMM INCUCELL 707 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 707-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume707 l depth520 mm width940 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)920×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven130 kg/oven per tray50 kg/tray Door 2 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width1160 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width1230 mm depth2085 mm Weight brut240 kg nett215 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 59 min Heat emission at 37 °C 85 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,9 kW nominal voltage230 V current3,9 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-707-eco-lineStorm™ Heating/Cooling Work Station
Tekli yada çoklu karıştırmalı reaktör ile kullanılabilinir. Thermo sıvı ve soğutucu kapasitesine bağlı olarak -85°C...+235°C aralığında çalışabilir. M24 bağlantı ile tüm soğutucular ile kolayca bağlantı imkanı sunar.
https://www.info-tek.com.tr/storm-heatingcooling-work-stationIncubation/Inactivation Bath Order No 1112
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1112Spares + consumables for pellet dies | FTIR, KBr + XRF
Die Bases Die Extractor Rings Retainer Rings O-Rings Pellet Holders Die Spares
https://www.info-tek.com.tr/spares-consumables-for-pellet-dies-ftir-kbr-xrfMMM Durocell 22 - ECO line
Highly durable laboratory oven 22-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-22-eco-lineMMM INCUCELL V 22 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 22-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume22 l depth320 mm width240 mm height300 mm Tray standard equipment2 pcs storage area (w × d)185×265 mm racks4 max. number distance between guide rails60 mm Maximal weight of the load *) inside the oven25 kg/oven per tray10 kg/tray Door 1 pcs External dimensions (including door and handle) depth560 mm diameter of the air branch outer/inner52/49 mm width406 mm height, incl. Feet (N) and Rolls (K)610 (N) Package dimensions (three layers carton) depth720 mm width500 mm depth810 mm Weight brut36 kg nett31 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)0,1 °C space deviation cca (±)0,4 °C Time required to reach 37 °C with closed air flap and voltage 230 V 8 min Heat emission at 37 °C 70 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,96 kW nominal voltage230 V current4,2 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-22Breeze™ Heating/Cooling Work Station
Hızlı ısıtma/soğutma sayesinde 5 litrelik balonlarda bile kolay ve güvenli çalışma imkanı sunar. Thermo sıvı ve soğutucu kapasitesine bağlı olarak -85°C...+235°C aralığında çalışabilir. C6 plus, tornado ve Heat-On ile kolay kullanım sağlar. M16 bağlantı ile tüm soğutucularla kolay bağlantı imkanı sunar.
https://www.info-tek.com.tr/breeze-heatingcooling-work-stationIncubation/Inactivation Bath Order No 1113
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1113MMM Durocell 55 - ECO line
Highly durable laboratory oven 55-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-55-eco-lineMMM INCUCELL V 55 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 55-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume55 l depth370 mm width400 mm height350 mm Tray standard equipment2 pcs storage area (w × d)380×335 mm racks4 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width620 mm height, incl. Feet (N) and Rolls (K)680 (N) Package dimensions (three layers carton) depth730 mm width700 mm depth875 mm Weight brut66 kg nett55 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 41 min Heat emission at 37 °C 80 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-55-eco-lineIncubation/Inactivation Bath Order No 1002
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1002MMM Durocell 111 - ECO line
Highly durable laboratory oven 111-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-111-eco-lineMMM INCUCELL V 111 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 111-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume111 l depth370 mm width540 mm height530 mm Tray standard equipment2 pcs storage area (w × d)520×335 mm racks7 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)860 (N) Package dimensions (three layers carton) depth730 mm width830 mm depth1060 mm Weight brut87 kg nett75 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 51 min Heat emission at 37 °C 95 W Air exchange speed at 37 °C 49 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-111-eco-lineIncubation/Inactivation Bath Order No 1003
Applications The Water Bath is successfully used for incubations and inactivations of cultures, as well as e. g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1003