• Örnek Mah. Ercüment Batanay Sk. No:14/E D:14 Zemin Kat Dumankaya İkon Ataşehir / İSTANBUL
  • +90 216 291 19 51
  • [javascript protected email address]

Arama Sonuçları..

Toplam 8 kayıt bulundu.
GPR 11-37E Model Refraktometreler

GPR 11-37E Model Refraktometreler

Yüksek Sıcaklık Refraktometreleri   GPR 11-37 E Model Refraktometreler Peltier Isıtmalı - soğutmalı refraktometreler olup petrokimya endüstrisi için özel olarak dizayn edilmiş yüksek sıcaklıktaki refraktometreleridir.

https://www.info-tek.com.tr/gpr-11-37e-model-refraktometreler

Radleys Mya 4 Reaction Station

Radleys Mya 4 Reaction Station

A 4-zone reaction station offering safe and precise heating, active cooling,software control and data-logging for 24/7 unattended chemistry

https://www.info-tek.com.tr/mya-4-reaction-station

ISF1-Z incubator shaker

ISF1-Z incubator shaker

ISF1-Z inkübatör çalkalayıcı, laboratuvarlardaki, araştırma merkezlerindeki ve üretim tesislerindeki uygulamalar için uygundur.İnkübatör çalkalayıcı, mikrobiyal, bitki ve hayvan hücre kültürleri için uygulanabilir.

https://www.info-tek.com.tr/isf1-z-incubator-shaker-1

VariDens

VariDens

Specifications VariDens C VariDens B Measuring range 0 – 3 g/cm3 Temperature range 10 – 95 °C* (regulated Peltier thermoelement) Pressure range 0 to 10 bar, (0 to 1 MPa) Density accuracy ± 0.0005 g/cm3 ± 0.00005 g/cm3 Resolution 0.0001 g/cm3 0.00001 g/cm3 Reproducibility ± 0.0002 g/cm3 ± 0.00002 g/cm3 Temperature accuracy ± 0.05 °C ± 0.03 °C Resolution 0.01 °C 0.001 °C Reproducibility ± 0.02 °C ± 0.01 °C Wetted parts Borosilicate glass, PTFE Bubble detection Yes (combined: visual-electronic) Drying Integrated air pump Temperature compensation Yes Minimum sample amount Approx. 1.5 ml Measuring time per sample** < 10 sec < 30 sec Display None or 7″ touchscreen, 800 x 480 Pixel Interfaces Ethernet 10/100/1000, RS232, SuH-Connector, USB, WLAN***, Modbus***, Canbus***, Profibus*** Ambient conditions Temperature 10 °C to 35 °C, Humidity < 85% not condensing Power supply VAC 90-265; 50/60 Hz; 150 maximum Dimensions With display: 310 x 220 x 235 mm (W x D x H) / without display: 310 x 220 x 150 mm (W x D x H) Standards International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others

https://www.info-tek.com.tr/varidens

LAUDA TD4

LAUDA TD4

The TD4 is a compact ring/plate tensiometer, which, as a standalone device, offers maximum ease of use in research and development, as well as for quality control. The graphic operating unit with touch-screen enables accurate tracking of measurements (even time-dependent measurements). The pre-programmed standard methods, the GLP-compliant user management system, the optional equipment with a small Peltier-based thermostat (PTT+) and the intuitive user guiding make the TD4 a compact and precise measuring instrument.

https://www.info-tek.com.tr/lauda-td4

VariPol – Polarimeter

VariPol – Polarimeter

Teknik Özellikler:   Specifications VariPol C VariPol B Measurement scales ° Optical rotation, ° Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L),further scales freely definable Measuring range ± 89.9° Precision ± 0.01° * ± 0.005° * Repeatability ± 0.01° ± 0.005° Resolution 0.005° 0.001° Sensitivity Up to OD 3 Wavelength 1 or 2 wavelengths fixed, standard 589 nm, also available 365, 405, 436, 546 Measuring time 6 to 8 sec. over the entire measuring range Measuring tubes Up to 100 mm length; standard tubes, tubes with funnel or flow through; wetted parts: glass, stainless steel, Hastelloy Temperature measurement Pt1000 sensor (device) / NTC sensor (Quartz control plates and tubes) Sample temperature range 10 °C to 40 °C Temperature precision / resolution ± 0.1 °C* / 0.01 °C Peltier temp. regulation of the sample room 18 °C to 25 °C 10 °C to 40 °C Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C, with tube) Light source LED, interference filter Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC/Tablet/Smartphone*** Interfaces / Communication Ethernet 10/100/1000, RS232, USB, WLAN** Power VAC 90-265; 50/60 Hz; 150 W max Conformity International Pharmacopoeia, OIML, 21 CFR part 11, ICUMSA, Australian Standard K157 Dimensions With display: 430 x 300 x 270 mm (w x d x h); without display: 430 x 300 x 160 mm (w x d x h) Highlights Basic Polarimeter especially designed for pharmaceutical applications; Modularity; Fast measuring; Peltier system forautomatic temperature control; easy to calibrate; constant precision over the whole measuringrange, 21 CFR part 11ready; energy saving durable LEDs; ELN; LIMS ready  

https://www.info-tek.com.tr/aa-65-serisi-polarimetreler

ATR L Dispersion Refractometer

ATR L Dispersion Refractometer

SPESIFICATIONS ATR-L Measuring scales Refractive index (RI) Measuring range 1.33200 - 1.70000 RI* / 100% Brix Resolution 0.00001 RI* / 0.01 Brix Precision ± 0.00004 RI* / ± 0.03 Brix Reproductibility ± 0.00004 RI* / ± 0.03 Brix Measuring time per sample 20 sec for all 7 wavelength after temperature stabilisation; single sample measurement Ambient temperature + 15° to + 40°C Automatic temperature compensationOperational temperatureTemperature stabilityTemperature precision Solid state Peltier-thermostatisation+ 10°C to + 80°C0.01°C± 0.03°C Detector CCD-linear array with 2048 elements Sample compartment Used materials: stainless steel, Black Delrin®, Teflon®, Viton®, FFKM sealing Prism YAG Light source / Wavelength 7 discrete LED's with fixed wavelengths 400, 450, 490, 545, 590, 660, 700 nm (others on request),wavelength accuracy ± 2 nm Display LCD, 16 x 16 characters, back illuminated Operation 20 key membrane including function keys Interfaces /Communication 1 x RS232 C, 1x parallel, USB optional Standards                                                           European and international Pharmacopoeia, various ASTM, ISO and DIN standards Dimensions / Weight Mesuring head, stainless steel: 260 x 190 x 220 mm (w x h x d); control unit: 220 x 110 x 290 mm (w x h x d); complete unit 8 kg Highlights                                                                                                     Automatic dispersion measurement at 7 wavelengths over the full range of visibile light (intermediate values interpolated)**;Powerful, internal Peltier temperature control guarantees the fastest measurements with highest accuracy

https://www.info-tek.com.tr/atr-l-dispersion-refractometer

Duo Visc

Duo Visc

Routine viscosity measurements demand a high level of precision both in temperature and time measurement. The Duo.Visc with its two independent thermoelectric Peltier heating/cooling systems allows to have the most stable and precise measurements without consuming valuable bench-space in the laboratory. The wide range of available capillaries covers the complete viscosity range. The easy to use Duo.Visc software helps to meet the requirements of today’s laboratories.

https://www.info-tek.com.tr/duo-visc

-->
3WTURK CMS v6.0
-->